

Other manufacturers with similar products

Circuit breaker frame, MasterPact NT08H1, 800A, 42kA/440VAC 50/60Hz (Icu), 4 poles, drawout, without control unit, 17.828 kg/unit, 47215, Schneider Electric
Schneider Electric
99.8 kg CO2e/unit

Circuit breaker, ComPact NS1600N, 50kA/415VAC, Micrologic 5.0 trip unit, 1600A, fixed, 3 poles 3d, 14.141 kg/unit, 33568, Schneider Electric
Schneider Electric
197 kg CO2e/unit

Circuit breaker, EasyPact MVS, 3 Poles, 2500A, 50kA, MDO, ETV6, drawout, manual, 96.346 kg/unit, MVS25N3MW6V, Schneider Electric
Schneider Electric
676 kg CO2e/unit
EPD: Coils for circuit breaker, 0.418 kg/unit including packaging, - YU E1.2..E6.2-XT7-XT7M 24 Vac/dc - YU E1.2..E6.2-XT7-XT7M 30 Vac/dc - YU E1.2..E6.2-XT7-XT7M 48 Vac/dc - YU E1.2..E6.2-XT7-XT7M 60 Vac/dc - YU E1.2..E6.2-XT7-XT7M 110-120 Vac/dc - YU E1.2..E6.2-XT7-XT7M 120-127 Vac/dc - YU E1.2..E6.2-XT7-XT7M 220-240 Vac/dc - YU E1.2..E6.2-XT7-XT7M 240-250 Vac/dc - YU E1.2..E6.2-XT7-XT7M 277 Vac - YU E1.2..E6.2-XT7-XT7M 380-400 Vac - YU E1.2..E6.2-XT7-XT7M 415-440 Vac - YU E1.2..E6.2-XT7-XT7M 480-500 Vac - YU E1.2..E6.2-XT7-XT7M 500-550 Vac - YU E1.2..E6.2-XT7/XT7M 220-240 Vac/dc, ABB ASEA BROWN BOVERI LTD / ABB ASEA BROWN BOVERI
Enhance your circuit protection with the YU E1.2..E6.2-XT7-XT7M coils. Available in various voltage ratings, these coils deliver reliable performance and longevity for your circuit breakers, ensuring optimal functionality in critical applications.
This coil accessory operates the TMAX XT series molded case circuit breakers and Emax 2 ACB, enabling precise opening and closing functions. It features robust construction for long-term reliability and is designed for easy integration into existing sys...
Manufacturer:
ABB ASEA BROWN BOVERI LTD / ABB ASEA BROWN BOVERI
Group:
Country of production:
Product name:
Coils for circuit breaker
Commercial names:
- YU E1.2..E6.2-XT7-XT7M 24 Vac/dc - YU E1.2..E6.2-XT7-XT7M 30 Vac/dc - YU E1.2..E6.2-XT7-XT7M 48 Vac/dc - YU E1.2..E6.2-XT7-XT7M 60 Vac/dc - YU E1.2..E6.2-XT7-XT7M 110-120 Vac/dc - YU E1.2..E6.2-XT7-XT7M 120-127 Vac/dc - YU E1.2..E6.2-XT7-XT7M 220-240 Vac/dc - YU E1.2..E6.2-XT7-XT7M 240-250 Vac/dc - YU E1.2..E6.2-XT7-XT7M 277 Vac - YU E1.2..E6.2-XT7-XT7M 380-400 Vac - YU E1.2..E6.2-XT7-XT7M 415-440 Vac - YU E1.2..E6.2-XT7-XT7M 480-500 Vac - YU E1.2..E6.2-XT7-XT7M 500-550 Vac - YU E1.2..E6.2-XT7/XT7M 220-240 Vac/dc
Category:
Installations and systems
Class:
Electrification components and systems
Type:
Breakers and fuses
Environmental impacts
Global Warming Potential (A1-A3):
5.94 kg CO2e/unit
Technical specification:
0.418 kg/unit including packaging
Available units for calculation:
unit, kg, ton
Unique identifier (OCLID):
67cb3d1329928151a92f1e94
Sustainability data background information
EPD number:
ABBG-00388-V01.01-EN
EPD program:
PEP-ecopassport
Publication year:
2024
Product Category Rules (PCR):
PEP-PCR-ed4-2021 09 06
Environmental standard:
EN15804+A2
Data source:
PEP
Verification status:
Third-party verified (as per ISO 14025)
Upstream database:
ecoinvent