Other manufacturers with similar products

Circuit breaker frame, MasterPact NT08H1, 800A, 42kA/440VAC 50/60Hz (Icu), 4 poles, drawout, without control unit, 17.828 kg/unit, 47215, Schneider Electric
Schneider Electric
99.8 kg CO2e/unit

Circuit breaker, ComPact NS1600N, 50kA/415VAC, Micrologic 5.0 trip unit, 1600A, fixed, 3 poles 3d, 14.141 kg/unit, 33568, Schneider Electric
Schneider Electric
197 kg CO2e/unit

Circuit breaker, EasyPact MVS, 3 Poles, 2500A, 50kA, MDO, ETV6, drawout, manual, 96.346 kg/unit, MVS25N3MW6V, Schneider Electric
Schneider Electric
676 kg CO2e/unit
EPD: Coils for circuit breakers, 0.246 kg/unit including packaging, - SOR XT1..XT4 12 Vdc - SOR XT1..XT4 24-30 Vac/dc - SOR XT1..XT4 48-60 Vac/dc - SOR XT1..XT4 110...127 Vac-110...125 Vdc - SOR XT1..XT4 220...240 Vac-220...250 Vdc - SOR XT1..XT4 380-440 Vac - SOR XT1..XT4 480-525 Vac - SOR-C XT1..XT4 F/P 12 Vdc - SOR-C XT1..XT4 F/P 24-30 Vac/dc - SOR-C XT1..XT4 F/P 48-60 Vac/dc - SOR-C XT1..XT4 F/P 110-127Vac-110-125Vdc - SOR-C XT1..XT4 F/P 220-240Vac-220-250Vdc - SOR-C XT1..XT4 F/P 380-440 Vac - SOR-C XT1..XT4 F/P 480-525 Vac - SOR-C XT2-XT4 W 12 Vdc - SOR-C XT2-XT4 W 24-30 Vac/dc - SOR-C XT2-XT4 W 48-60 Vac/dc - SOR-C XT2-XT4 W 110-127Vac-110-125Vdc - SOR-C XT2-XT4 W 220-240Vac-220-250Vdc - SOR-C XT2-XT4 W 380-440 Vac - SOR-C XT2-XT4 W 480-525 Vac, ABB ASEA BROWN BOVERI LTD / ABB ASEA BROWN BOVERI
Discover the versatility of SOR coil accessories, compatible with TMAX XT and Emax 2 circuit breakers, offering robust performance from 12Vdc to 525Vac. Reliable and efficient, they ensure seamless operation for your electrical needs.
These coils are designed to efficiently open or close circuit breakers in the TMAX XT series and Emax 2 ACBs. They operate with a range of nominal voltages, providing dependable performance in various electrical applications.
The coils are easily installed in TMAX XT...
Manufacturer:
ABB ASEA BROWN BOVERI LTD / ABB ASEA BROWN BOVERI
Group:
Country of production:
Product name:
Coils for circuit breakers
Commercial names:
- SOR XT1..XT4 12 Vdc - SOR XT1..XT4 24-30 Vac/dc - SOR XT1..XT4 48-60 Vac/dc - SOR XT1..XT4 110...127 Vac-110...125 Vdc - SOR XT1..XT4 220...240 Vac-220...250 Vdc - SOR XT1..XT4 380-440 Vac - SOR XT1..XT4 480-525 Vac - SOR-C XT1..XT4 F/P 12 Vdc - SOR-C XT1..XT4 F/P 24-30 Vac/dc - SOR-C XT1..XT4 F/P 48-60 Vac/dc - SOR-C XT1..XT4 F/P 110-127Vac-110-125Vdc - SOR-C XT1..XT4 F/P 220-240Vac-220-250Vdc - SOR-C XT1..XT4 F/P 380-440 Vac - SOR-C XT1..XT4 F/P 480-525 Vac - SOR-C XT2-XT4 W 12 Vdc - SOR-C XT2-XT4 W 24-30 Vac/dc - SOR-C XT2-XT4 W 48-60 Vac/dc - SOR-C XT2-XT4 W 110-127Vac-110-125Vdc - SOR-C XT2-XT4 W 220-240Vac-220-250Vdc - SOR-C XT2-XT4 W 380-440 Vac - SOR-C XT2-XT4 W 480-525 Vac
Category:
Installations and systems
Class:
Electrification components and systems
Type:
Breakers and fuses
Environmental impacts
Global Warming Potential (A1-A3):
4.21 kg CO2e/unit
Technical specification:
0.246 kg/unit including packaging
Available units for calculation:
unit, kg, ton
Unique identifier (OCLID):
67cb3d2f29928151a92f1ec6
Sustainability data background information
EPD number:
ABBG-00384-V01.01-EN
EPD program:
PEP-ecopassport
Publication year:
2024
Product Category Rules (PCR):
PEP-PCR-ed4-2021 09 06
Environmental standard:
EN15804+A2
Data source:
PEP
Verification status:
Third-party verified (as per ISO 14025)
Upstream database:
ecoinvent