Other manufacturers with similar products
Circuit breaker frame, MasterPact NT08H1, 800A, 42kA/440VAC 50/60Hz (Icu), 4 poles, drawout, without control unit, 17.828 kg/unit, 47215, Schneider Electric
Schneider Electric
99.8 kg CO2e/unit
Circuit breaker, ComPact NS1600N, 50kA/415VAC, Micrologic 5.0 trip unit, 1600A, fixed, 3 poles 3d, 14.141 kg/unit, 33568, Schneider Electric
Schneider Electric
197 kg CO2e/unit
Circuit breaker, EasyPact MVS, 3 Poles, 2500A, 50kA, MDO, ETV6, drawout, manual, 96.346 kg/unit, MVS25N3MW6V, Schneider Electric
Schneider Electric
676 kg CO2e/unit
EPD: Four pole air circuit breaker, 90.34 kg/unit, HW2E406FE, HW2E406FB, HW2E408FB, HW2E408FE, HW2E410FB, HW2E410FE, HW2E412FB, HW2E412FE, HW2E416FB, HW2E416FE, HW2E420FB, HW2E420FE, HW2E425FB, HW2E425FE, HW2M406FB, HW2M406FE, HW2M408FB, HW2M408FE, HW2M410FB, HW2M410FE, HW2M412FB, HW2M412FE, HW2M416FB, HW2M416FE, HW2M420FB, HW2M420FE, HW2M425FB, HW2M425FE, HW2S406FB, HW2S406FE, HW2S408FB, HW2S408FE, HW2S410FB, HW2S410FE, HW2S412FB, HW2S412FE, HW2S416FB, HW2S416FE, HW2S420FB, HW2S420FE, HW2S425FB, HW2S425FE (with terminals HWY161H), HAGER / HAGER SE
Discover the HW series Four pole air circuit breakers, engineered for superior performance and safety. With various commercial names, these breakers excel in efficiency, ensuring optimal protection for your electrical systems.
The Four pole air circuit breaker offers reliable protection against overloads and short circuits. Its compact design and robust construction ensure durability. User-friendly interface facilitates easy operation and monitoring.
Ideal for industrial and commercial application...
Manufacturer:
HAGER / HAGER SE
Group:
Country of production:
Product name:
Four pole air circuit breaker
Commercial names:
HW2E406FE, HW2E406FB, HW2E408FB, HW2E408FE, HW2E410FB, HW2E410FE, HW2E412FB, HW2E412FE, HW2E416FB, HW2E416FE, HW2E420FB, HW2E420FE, HW2E425FB, HW2E425FE, HW2M406FB, HW2M406FE, HW2M408FB, HW2M408FE, HW2M410FB, HW2M410FE, HW2M412FB, HW2M412FE, HW2M416FB, HW2M416FE, HW2M420FB, HW2M420FE, HW2M425FB, HW2M425FE, HW2S406FB, HW2S406FE, HW2S408FB, HW2S408FE, HW2S410FB, HW2S410FE, HW2S412FB, HW2S412FE, HW2S416FB, HW2S416FE, HW2S420FB, HW2S420FE, HW2S425FB, HW2S425FE (with terminals HWY161H)
Category:
Installations and systems
Class:
Electrification components and systems
Type:
Breakers and fuses
Environmental impacts
Global Warming Potential (A1-A3):
0.362 kg CO2e/unit
Technical specification:
90.34 kg/unit
Available units for calculation:
unit, kg, ton
Unique identifier (OCLID):
66c8cd7fd284ea28936950c8
Sustainability data background information
EPD number:
HAGE-00757-V03.01
EPD program:
PEP-ecopassport
Publication year:
2024
Product Category Rules (PCR):
PEP-PCR-ed4-2021 09 06
Environmental standard:
EN15804+A2
Data source:
PEP
Verification status:
Third-party verified (as per ISO 14025)
Upstream database:
ecoinvent