Circuit breaker frame, MasterPact NT08H1, 800A, 42kA/440VAC 50/60Hz (Icu), 4 poles, drawout, without control unit, 17.828 kg/unit, 47215, Schneider Electric

Schneider Electric

99.8 kg CO2e/unit
Material Image

Circuit breaker, ComPact NS1600N, 50kA/415VAC, Micrologic 5.0 trip unit, 1600A, fixed, 3 poles 3d, 14.141 kg/unit, 33568, Schneider Electric

Schneider Electric

197 kg CO2e/unit
Material Image

Circuit breaker, EasyPact MVS, 3 Poles, 2500A, 50kA, MDO, ETV6, drawout, manual, 96.346 kg/unit, MVS25N3MW6V, Schneider Electric

Schneider Electric

676 kg CO2e/unit
unverified-manufacturerPagina del produttore.

DEP: Molded case circuit breaker with thermal magnetic trip unit, 690 V, 1.7524 kg/unit, - XT3 3p IEC C-N-S TMD R80 - XT3 3p IEC C-N-S TMD R100 - XT3 3p IEC C-N-S TMD R125 - XT3 3p IEC C-N-S TMD R160 - XT3 3p IEC C-N-S TMD R200 - XT3 3p IEC C-N-S TMD R250 - XT3 3p IEC - D R250 - XT3 3p IEC C-N-S GM R250 - XT3 3p IEC C-N-S TMG R160 - XT3 3p IEC C-N-S TMG R63 - XT3 3p IEC C-N-S TMG R80 - XT3 3p IEC C-N-S TMG R100 - XT3 3p IEC C-N-S TMG R125 - XT3 3p IEC C-N-S TMG R200 - XT3 3p IEC C-N-S TMG R250 - XT3 3p IEC C-N-S MA R100 - XT3 3p IEC C-N-S MA R125 - XT3 3p IEC C-N-S MA R160 - XT3 3p IEC C-N-S MA R200 - XT3 3p IEC C-N-S MA R220 - XT3 3p UL N-S TMF R100 - XT3 3p UL N-S TMF R110 - XT3 3p UL N-S TMF R150 - XT3 3p UL N-S TMF R60 - XT3 3p UL N-S TMF R70 - XT3 3p UL N-S TMF R80 - XT3 3p UL N-S TMF R90 - XT3 3p UL N-S TMF R125 - XT3 3p UL N-S TMF R175 - XT3 3p UL N-S TMF R200 - XT3 3p UL N-S TMF R225 - XT3 3p UL N-S MCS R225 - XT3 3p UL S MCP R100 - XT3 3p UL S MCP R110 - XT3 3p UL S MCP R125 - XT3 3p UL S MCP R150 - XT3 3p UL S MCP R200 - XT3 4p IEC C-N-S TMD R80 - XT3 4p IEC C-N-S TMD R100 - XT3 4p IEC C-N-S TMD R125 - XT3 4p IEC C-N-S TMD R160 - XT3 4p IEC C-N-S TMD R200 - XT3 4p IEC C-N-S TMD R250 - XT3 4p IEC - D R250 - XT3 4p IEC C-N-S GM R250 - XT3 4p IEC C-N-S TMG R160 - XT3 4p IEC C-N-S TMG R63 - XT3 4p IEC C-N-S TMG R80 - XT3 4p IEC C-N-S TMG R100 - XT3 4p IEC C-N-S TMG R125 - XT3 4p IEC C-N-S TMG R200 - XT3 4p IEC C-N-S TMG R250 - XT3 4p UL N-S TMF R100 - XT3 4p UL N-S TMF R110 - XT3 4p UL N-S TMF R150 - XT3 4p UL N-S TMF R60 - XT3 4p UL N-S TMF R70 - XT3 4p UL N-S TMF R80 - XT3 4p UL N-S TMF R90 - XT3 4p UL N-S TMF R125 - XT3 3p IEC C-N-S TMD 250A, ABB ASEA BROWN BOVERI / ABB ASEA BROWN BOVERI LTD

Prova una protezione affidabile con gli interruttori a cassa stampati XT3, offrendo una varietà di modelli con unità di viaggio magnetiche termiche che garantiscono una risposta rapida ai guasti, migliorando la sicurezza e la longevità del sistema.

Interruttori a circuito stampato con unità di trasmissione magnetica termica proteggono i circuiti elettrici da sovraccarichi e cortocircuiti. Hanno un design compatto per una facile installazione e interfacce user-friendly.

Questi interruttori sono ide...

Produttore:
ABB ASEA BROWN BOVERI / ABB ASEA BROWN BOVERI LTD
Gruppo:
Paese di produzione:
IT country flagItalia
Nome del prodotto:
Molded case circuit breaker with thermal magnetic trip unit
Nomi commerciali:
- XT3 3p IEC C-N-S TMD R80 - XT3 3p IEC C-N-S TMD R100 - XT3 3p IEC C-N-S TMD R125 - XT3 3p IEC C-N-S TMD R160 - XT3 3p IEC C-N-S TMD R200 - XT3 3p IEC C-N-S TMD R250 - XT3 3p IEC - D R250 - XT3 3p IEC C-N-S GM R250 - XT3 3p IEC C-N-S TMG R160 - XT3 3p IEC C-N-S TMG R63 - XT3 3p IEC C-N-S TMG R80 - XT3 3p IEC C-N-S TMG R100 - XT3 3p IEC C-N-S TMG R125 - XT3 3p IEC C-N-S TMG R200 - XT3 3p IEC C-N-S TMG R250 - XT3 3p IEC C-N-S MA R100 - XT3 3p IEC C-N-S MA R125 - XT3 3p IEC C-N-S MA R160 - XT3 3p IEC C-N-S MA R200 - XT3 3p IEC C-N-S MA R220 - XT3 3p UL N-S TMF R100 - XT3 3p UL N-S TMF R110 - XT3 3p UL N-S TMF R150 - XT3 3p UL N-S TMF R60 - XT3 3p UL N-S TMF R70 - XT3 3p UL N-S TMF R80 - XT3 3p UL N-S TMF R90 - XT3 3p UL N-S TMF R125 - XT3 3p UL N-S TMF R175 - XT3 3p UL N-S TMF R200 - XT3 3p UL N-S TMF R225 - XT3 3p UL N-S MCS R225 - XT3 3p UL S MCP R100 - XT3 3p UL S MCP R110 - XT3 3p UL S MCP R125 - XT3 3p UL S MCP R150 - XT3 3p UL S MCP R200 - XT3 4p IEC C-N-S TMD R80 - XT3 4p IEC C-N-S TMD R100 - XT3 4p IEC C-N-S TMD R125 - XT3 4p IEC C-N-S TMD R160 - XT3 4p IEC C-N-S TMD R200 - XT3 4p IEC C-N-S TMD R250 - XT3 4p IEC - D R250 - XT3 4p IEC C-N-S GM R250 - XT3 4p IEC C-N-S TMG R160 - XT3 4p IEC C-N-S TMG R63 - XT3 4p IEC C-N-S TMG R80 - XT3 4p IEC C-N-S TMG R100 - XT3 4p IEC C-N-S TMG R125 - XT3 4p IEC C-N-S TMG R200 - XT3 4p IEC C-N-S TMG R250 - XT3 4p UL N-S TMF R100 - XT3 4p UL N-S TMF R110 - XT3 4p UL N-S TMF R150 - XT3 4p UL N-S TMF R60 - XT3 4p UL N-S TMF R70 - XT3 4p UL N-S TMF R80 - XT3 4p UL N-S TMF R90 - XT3 4p UL N-S TMF R125 - XT3 3p IEC C-N-S TMD 250A
Tipo:
Interruttori e fusibili

Impatto ambientale

Potenziale di riscaldamento globale (A1-A3):
12.8 kg CO2e/unit
Specifiche tecniche:
690 V, 1.7524 kg/unit
Unità disponibili per il calcolo:
unit, kg, ton
Identificatore univoco (OCLID):
66926c061040414eaa25ceaf

Informazioni di base sui dati di sostenibilità

Numero dell'EPD:
ABBG-00019-V01.06
Programma EPD:
PEP-ecopassport
Anno di pubblicazione:
2022
Regole di categoria di prodotto (PCR):
PEP-PCR-ed4-2021 09 06
Norma ambientale:
EN15804+A2
Fonte dei dati:
PEP
Stato di verifica:
Third-party verified (as per ISO 14025)
Banca dati a monte:
ecoinvent